Anunțul 673108-2026 pentru Danemarca – Spectrometre de masă – Orbital Tribrid APEX og Orbitrap Astral Zoom este publicat de Københavns Universitet și este încadrat la codul CPV 38433100.
Sinteză HarveyAI
Harvey procesează documentele acestei licitații...
The contract can be provided only by a particular economic operator who can comply with the set requirements.
Award criterion number LOT
100
Award criterion number weight LOT
per-exa
Award criterion type LOT
quality
Contract conclusion date
2026-09-23Z
Contract identifier
04 ••• ••• 00
Contract nature
supplies
Contract nature main LOT
supplies
Contract nature main PROC
supplies
Contract tender id
TEN-0001
Contract title
Kontrakt om levering af to massespektrometre mv.
Result LOT identifier
LOT-0000
Result value CUR NOTICE
DKK
Result value NOTICE
8532615.03
Organizații și puncte de contact63
Organisation city buyer
København K
Organisation city financing
København K
Organisation city paying
København K
Organisation city reviewinfo LOT
Valby
Organisation city revieworg LOT
Viborg
Organisation city signatory
København K
Organisation city ted esen
Oslo
Organisation city tenderer
Allerød
Organisation country buyer
DNK
Alte informații publicate17
Additional info PROC
Kan ikke opdeles efter sit indhold
Direct award justification PROC
technical
Direct award justification text PROC
Thermo Fisher Scientific is the only economic operator capable of supplying the complete required configuration comprising one Orbitrap Astral Zoom, one Orbitrap Tribrid APEX, two FAIMS Pro Duo interfaces, and two Vanquish Neo UHPLC systems. The Orbitrap Astral Zoom and Orbitrap Tribrid APEX are proprietary mass-spectrometry platforms developed, manufactured, and sold exclusively by Thermo Fisher Scientific. The specific combination of technologies incorporated into these systems—including the Orbitrap mass analyzer, Astral analyzer, Tribrid architecture, FAIMS Pro Duo interface, and IR-laser-enabled fragmentation—is unique to Thermo Fisher Scientific and is not available from any other manufacturer. The two mass spectrometers are not interchangeable but provide complementary capabilities required for PRI’s scientific activities and proteomics services. Orbitrap Astral Zoom The Orbitrap Astral Zoom combines a high-selectivity quadrupole mass filter, a high-resolution Orbitrap analyzer, and the proprietary Astral analyzer within one instrument. While the Orbitrap analyzer provides high-resolution, accurate-mass full-scan analysis with resolution settings of up to 480,000 FWHM at m/z 200, the Astral analyzer provides ultrafast, high-resolution MS/MS acquisition at rates of up to 270 Hz. The parallelized instrument architecture provides the acquisition speed, sensitivity, mass resolution, and quantitative performance required for: • narrow-window data-independent acquisition; • high-throughput analysis using short LC gradients; • large-cohort plasma and tissue proteomics; • low-input and single-cell proteomics; • deep proteome coverage at throughputs of up to 300 samples per day; and • multiplexed quantitative proteomics using TMTpro reagents. Other manufacturers offer high-performance mass spectrometers suitable for individual proteomics applications. However, no other supplier offers an instrument that combines an Orbitrap analyzer with the proprietary Astral analyzer and provides an equivalent combination of acquisition speed, mass resolution, sensitivity, ion-processing parallelization, and compatibility with PRI’s established Orbitrap Astral workflows. Orbitrap Tribrid APEX The Orbitrap Tribrid APEX provides advanced analytical capabilities that cannot be delivered by the Orbitrap Astral Zoom. Its proprietary Tribrid architecture combines quadrupole precursor selection, ion-trap analysis, high-resolution Orbitrap detection, extensive ion-processing parallelization, and multistage MSⁿ acquisition within a single instrument. The required APEX configuration additionally provides: • synchronous precursor selection MS³; • real-time library searching and adaptive acquisition; • collision-induced dissociation; • higher-energy collisional dissociation; • electron-transfer dissociation; • electron-transfer/higher-energy collision dissociation; and • IR-laser-enabled activation and infrared multiphoton dissociation. These complementary fragmentation and acquisition capabilities are required for advanced TMTpro multiplexed quantification, targeted TMT workflows, glycoproteomics, cross-linking mass spectrometry, immunopeptidomics, detailed characterization and localization of post-translational modifications, and structural and top-down proteomics. In particular, synchronous precursor selection MS³ is required to reduce reporter-ion interference and improve quantitative accuracy in complex TMTpro experiments. Real-time library searching and adaptive acquisition enable detected peptides to be identified during acquisition and directed into targeted confirmatory experiments. ETD and EThcD enable peptide-backbone fragmentation while preserving labile post-translational modifications, improving peptide-sequence coverage and modification-site localization. The integrated IR laser further expands the available fragmentation and structural-proteomics workflows and improves reporter-ion generation in multiplexed quantitative experiments. Although other suppliers offer high-performance mass spectrometers capable of addressing some of these applications, no alternative supplier offers the required combination of Orbitrap detection, Tribrid MSⁿ architecture, SPS-MS³, real-time adaptive acquisition, ETD/EThcD, and integrated IR-laser-enabled fragmentation.
I henhold til lov om Klagenævnet for Udbud gælder følgende frist for indgivelse af klage: Senest samtidig med at en klage indgives til Klagenævnet for Udbud, skal klageren skriftligt underrette ordregiveren om, at klage indgives til Klagenævnet for Udbud, og om, hvorvidt klagen er indgivet i den periode på 10 kalenderdage, som er fastsat i § 4, stk. 1, nr. 2. I tilfælde, hvor klagen ikke er indgivet i denne periode, skal klageren tillige angive, hvorvidt der begæres opsættende virkning af klagen, jf. § 12, stk. 1. Herefter klagefrist på 30 kalenderdage for klage over en ordregivers beslutning om, at ordregiveren har til hensigt at indgå kontrakt med en bestemt virksomhed og har anvendt proceduren i § 4. Klagefristen løber fra offentliggørelsen af bekendtgørelse om indgåelse af kontrakt, jf. § 7, stk. 3.
Date de contact publicate în TED
22
Contactele sunt disponibile utilizatorilor autentificați.Autentifică-te
Textul integral publicat de TEDextinde
Kontrakt om levering af to massespektrometre mv.
Thermo Fisher Scientific is the only economic operator capable of supplying the complete required configuration comprising one Orbitrap Astral Zoom, one Orbitrap Tribrid APEX, two FAIMS Pro Duo interfaces, and two Vanquish Neo UHPLC systems. The Orbitrap Astral Zoom and Orbitrap Tribrid APEX are proprietary mass-spectrometry platforms developed, manufactured, and sold exclusively by Thermo Fisher Scientific. The specific combination of technologies incorporated into these systems—including the Orbitrap mass analyzer, Astral analyzer, Tribrid architecture, FAIMS Pro Duo interface, and IR-laser-enabled fragmentation—is unique to Thermo Fisher Scientific and is not available from any other manufacturer. The two mass spectrometers are not interchangeable but provide complementary capabilities required for PRI’s scientific activities and proteomics services. Orbitrap Astral Zoom The Orbitrap Astral Zoom combines a high-selectivity quadrupole mass filter, a high-resolution Orbitrap analyzer, and the proprietary Astral analyzer within one instrument. While the Orbitrap analyzer provides high-resolution, accurate-mass full-scan analysis with resolution settings of up to 480,000 FWHM at m/z 200, the Astral analyzer provides ultrafast, high-resolution MS/MS acquisition at rates of up to 270 Hz. The parallelized instrument architecture provides the acquisition speed, sensitivity, mass resolution, and quantitative performance required for: • narrow-window data-independent acquisition; • high-throughput analysis using short LC gradients; • large-cohort plasma and tissue proteomics; • low-input and single-cell proteomics; • deep proteome coverage at throughputs of up to 300 samples per day; and • multiplexed quantitative proteomics using TMTpro reagents. Other manufacturers offer high-performance mass spectrometers suitable for individual proteomics applications. However, no other supplier offers an instrument that combines an Orbitrap analyzer with the proprietary Astral analyzer and provides an equivalent combination of acquisition speed, mass resolution, sensitivity, ion-processing parallelization, and compatibility with PRI’s established Orbitrap Astral workflows. Orbitrap Tribrid APEX The Orbitrap Tribrid APEX provides advanced analytical capabilities that cannot be delivered by the Orbitrap Astral Zoom. Its proprietary Tribrid architecture combines quadrupole precursor selection, ion-trap analysis, high-resolution Orbitrap detection, extensive ion-processing parallelization, and multistage MSⁿ acquisition within a single instrument. The required APEX configuration additionally provides: • synchronous precursor selection MS³; • real-time library searching and adaptive acquisition; • collision-induced dissociation; • higher-energy collisional dissociation; • electron-transfer dissociation; • electron-transfer/higher-energy collision dissociation; and • IR-laser-enabled activation and infrared multiphoton dissociation. These complementary fragmentation and acquisition capabilities are required for advanced TMTpro multiplexed quantification, targeted TMT workflows, glycoproteomics, cross-linking mass spectrometry, immunopeptidomics, detailed characterization and localization of post-translational modifications, and structural and top-down proteomics. In particular, synchronous precursor selection MS³ is required to reduce reporter-ion interference and improve quantitative accuracy in complex TMTpro experiments. Real-time library searching and adaptive acquisition enable detected peptides to be identified during acquisition and directed into targeted confirmatory experiments. ETD and EThcD enable peptide-backbone fragmentation while preserving labile post-translational modifications, improving peptide-sequence coverage and modification-site localization. The integrated IR laser further expands the available fragmentation and structural-proteomics workflows and improves reporter-ion generation in multiplexed quantitative experiments. Although other suppliers offer high-performance mass spectrometers capable of addressing some of these applications, no alternative supplier offers the required combination of Orbitrap detection, Tribrid MSⁿ architecture, SPS-MS³, real-time adaptive acquisition, ETD/EThcD, and integrated IR-laser-enabled fragmentation.
Københavns Universitet
Klagenævnet for Udbud
Thermo Electron A/S
Kan ikke opdeles efter sit indhold
Orbital Tribrid APEX og Orbitrap Astral Zoom
The contract can be provided only by a particular economic operator who can comply with the set requirements.
Mercell Holding ASA
The Proteomics Research Infrastructure (PRI), University of Copenhagen, intends to acquire the following integrated LC–MS instrumentation: • one Thermo Scientific Orbitrap Astral Zoom mass spectrometer; • one Thermo Scientific Orbitrap Tribrid APEX mass spectrometer; • two Thermo Scientific FAIMS Pro Duo interfaces; and • two Thermo Scientific Vanquish Neo UHPLC systems. The purchase includes the associated ion sources, software, installation, integration, training, and service components
I henhold til lov om Klagenævnet for Udbud gælder følgende frist for indgivelse af klage: Senest samtidig med at en klage indgives til Klagenævnet for Udbud, skal klageren skriftligt underrette ordregiveren om, at klage indgives til Klagenævnet for Udbud, og om, hvorvidt klagen er indgivet i den periode på 10 kalenderdage, som er fastsat i § 4, stk. 1, nr. 2. I tilfælde, hvor klagen ikke er indgivet i denne periode, skal klageren tillige angive, hvorvidt der begæres opsættende virkning af klagen, jf. § 12, stk. 1. Herefter klagefrist på 30 kalenderdage for klage over en ordregivers beslutning om, at ordregiveren har til hensigt at indgå kontrakt med en bestemt virksomhed og har anvendt proceduren i § 4. Klagefristen løber fra offentliggørelsen af bekendtgørelse om indgåelse af kontrakt, jf. § 7, stk. 3.
Konkurrence- og Forbrugerstyrelsen
DNK
01
education
[telefon eliminat]
Askekroken 11
[email eliminat]
https://www.thermofisher.com/dk/en/home.html
none
https://www.kfst.dk
[telefon eliminat]
[telefon eliminat]
supplies
København K
8800
Nørregade 10
a083034c-b88f-4cf3-bd5e-15a993ab46c2
Viborg
DK041
CON-0001
quality
0
32014L0024
1
per-exa
2
can-standard
Allerød
http://www.ku.dk/
2000-01-01Z
2026-09-09Z
https://naevneneshus.dk/start-din-klage/klagenaevnet-for-udbud/
body-pl
37795526
2026-09-23Z
04 ••• ••• 29
TEN-0001
eforms-sdk-1.13
RES-0001
Nævnenes Hus, Toldboden 2
2200
[email eliminat]
38433100
complainants
980921565
[email eliminat]
DAN
0277
Carl Jacobsens vej 35
2.3
ted-esen
10294819
92c98c0a-3303-4aba-99e5-8d886e667a85-01
neg-wo-call
selec-w
DK011
14:01:05+00:00
DK013
t-med
DK012
2500
189/2026
ORG-0003
ORG-0004
ORG-0005
13:43:02+00:00
0431-0068/26-7000
ORG-0001
ORG-0002
Oslo
[telefon eliminat]
DKK
[telefon eliminat]
NO081
2026-09-28+00:00
3450
no-eu-funds
NOR
8532615.03
https://eu.eu-supply.com/ctm/company/companyinformation/index/166597
true
eSender
no
technical
1165
http://mercell.com/
medium
LOT-0000
DK28314388
Blegdamsvej 3B
TPA-0001
CPQ-00904920
københavn N
false
[email eliminat]
Tina Marie Møller
c47a667e-3f6e-4edd-99f5-cb02cf0f99c1
Valby
100
[telefon eliminat]+02:00
Loturi TED
1
0431-0068/26-7000
Orbital Tribrid APEX og Orbitrap Astral Zoom
The Proteomics Research Infrastructure (PRI), University of Copenhagen, intends to acquire the following integrated LC–MS instrumentation: • one Thermo Scientific Orbitrap Astral Zoom mass spectrometer; • one Thermo Scientific Orbitrap Tribrid APEX mass spectrometer; • two Thermo Scientific FAIMS Pro Duo interfaces; and • two Thermo Scientific Vanquish Neo UHPLC systems. The purchase includes the associated ion sources, software, installation, integration, training, and service components
38433100 — Spectrometre de masa
Rezultate și atribuiri TED
LOT-00008.532.615,03 DKK
Câștigător: Thermo Electron A/S · CUI DK28314388
Contract 04 ••• ••• 0023 sept. 2026
Detalii licitație
Descriere
The Proteomics Research Infrastructure (PRI), University of Copenhagen, intends to acquire the following integrated LC–MS instrumentation: • one Thermo Scientific Orbitrap Astral Zoom mass spectrometer; • one Thermo Scientific Orbitrap Tribrid APEX mass spectrometer; • two Thermo Scientific FAIMS Pro Duo interfaces; and • two Thermo Scientific Vanquish Neo UHPLC systems. The purchase includes the associated ion sources, software, installation, integration, training, and service components
Căutări relevante pentru 673108-2026
Legături interne utile pentru CPV, autoritate și expresiile principale din denumirea procedurii.