Anunțul 709857-2026 pentru Belgia – Spectrometre de masă – Upgrade FTICR 9.4T en solariX 7T 2xR à tête froide este publicat de Université de Liège și este încadrat la codul CPV 38433100.
Sinteză HarveyAI
Harvey procesează documentele acestei licitații...
Upgrade FTICR 9.4T en solariX 7T 2xR à tête froide
Result LOT identifier
LOT-0001
Result value CUR NOTICE
EUR
Result value NOTICE
247000.00
Alte informații publicate18
Dispatch date
2026-10-12+02:00
Dispatch date esender
2026-10-12T00:00:00+02:00
Dispatch time
00:00:00+02:00
Dispatch time esender
00:00:00+02:00
Official language
FRA
Ojs number
199/2026
Received submissions type code
tenders | part-req
Received submissions type val
1
Tender identifier
Bruker_Belgium_nv
Tender LOT identifier
Loc de executare5
Place of performance
BE100 | BEL
Place of performance country LOT
BEL
Place of performance country PROC
BEL
Place of performance subdiv LOT
BE100
Place of performance subdiv PROC
BE100
Organizații și puncte de contact59
Organisation city addinfo LOT
Liège
Organisation city buyer
Liège
Organisation city reviewinfo LOT
BRUXELLES
Organisation city revieworg LOT
BRUXELLES
Organisation city serv prov
Antwerpen / Anvers
Organisation city signatory
Liège
Organisation city ted esen
Brussels
Organisation city tenderer
Kontich
Organisation country addinfo LOT
BEL
Câștigători și oferte8
Winner city
Kontich
Winner country
BEL
Winner country sub
BE211
Winner identifier
04 ••• ••• 83
Winner name
Bruker Belgium nv
Winner post code
2550
Winner selection status
selec-w
Winner size
sme
Loturi4
Eu fund LOT
no-eu-funds
Gpa LOT
true
Identifier LOT
LOT-0001
Option description LOT
Options exigées (Maintenance préventive pendant 1 an)
Autoritate contractantă6
Authority main activity
education
Buyer identifier
ULiège
Buyer internet address
http://www.uliege.be/
Buyer legal type
pub-undert
Buyer post code
4000
Main activity
education
Valori2
Total value
247000
Total value CUR
EUR
Procedură și anunț5
Legal basis
32014L0024
Legal basis NOTICE
32014L0024
NOTICE preferred publication date
2026-10-14T00:00:00+02:00
Procedure identifier
72d0afaa-55fa-48fd-b3fd-405d39d603f4
Procedure type
open
Clasificare CPV2
Main classification type LOT
cpv
Main classification type PROC
cpv
Căi de atac1
Review deadline description LOT
Organisation fournissant les informations sur les recours et les délais : Conseil d'Etat
Date de contact publicate în TED
25
Contactele sunt disponibile utilizatorilor autentificați.Autentifică-te
Textul integral publicat de TEDextinde
Organisation fournissant les informations sur les recours et les délais : Conseil d'Etat
Options exigées (Maintenance préventive pendant 1 an)
Upgrade FTICR 9.4T en solariX 7T 2xR à tête froide
Le présent marché concerne la seconde étape d’un plan de mise à jour de notre instrumentation exceptionnelle, un FT-ICR solariX xR de Bruker (alias détection 1ω) en solariX 2xR (alias détection 2ω), c’est à dire deux cycles de détection par circonvolution des paquets d’ions dans la cellule ICR harmonisée dynamiquement, connue aussi sous le nom de ParaCell. Ce marché inclut l’upgrade de l’électronique pour la détection des ions en mode 2ω, et d’un aimant de seconde main compatible avec la détection 2ω d’au moins 7T et à consommation réduite en hélium liquide. La première étape de l’upgrade de notre FT-ICR comprenait entre autres la mise à jour de l’électronique de détection et de traitement des signaux de l’ICR via l’achat de la console NEO AVANCE. Cette console NEO est compatible avec la détection 2xR via l’ajout d’une carte électronique dédiée, qui fait l’objet de ce marché. Néanmoins la détection 2ω nécessite que les performances de l’aimant supraconducteur, notamment en termes d’homogénéité du champ magnétique, satisfasse les exigences de la détection 2ω. Cela nécessite donc de changer notre aimant supra-conducteur de 9.4T qui équipe actuellement notre solariX. C’est pourquoi un aimant de seconde main, d’au moins 7T, qui répond aux critères de performances imposés par la détection 2ω, fait partie de la demande de ce marché. En outre, et vu le contexte géopolitique actuel qui tend considérablement le marché de l’hélium liquide nécessaire au refroidissement de l’aimant supra-conducteur, l’aimant proposé devra être équipé d’un système dit de « tête froide » ou équivalent qui permet d’espacer annuellement les cycles de remplissage en hélium liquide, au lieu de tous les trimestres, avec l’aimant actuellement disponible au laboratoire de spectrométrie de masse. En plus de favoriser une utilisation de ce spectromètre de masse dans un contexte de développement durable, ce changement d’aimant a aussi pour vocation de pérenniser son fonctionnement via une consommation en hélium liquide nettement réduite car devenu une ressource hautement stratégique (usages militaire, médical, et scientifique) et à la disponibilité fortement limitée.
Conseil d'Etat
3P - Aanbieder van diensten / Prestataire de services
Prix
Université de Liège
FPS Policy and Support
Bruker Belgium nv
01
education
00:00:00+01:00
selec-w
part-req
04 ••• ••• 83
[telefon eliminat]
Sabine Goedhals
poi-exa
none
BE100
199/2026
Kartuizersweg 3B
72d0afaa-55fa-48fd-b3fd-405d39d603f4
[email eliminat]
supplies
ORG-0003
ORG-0004
ORG-0005
Gestionnaire de dossier
pub-undert
ORG-0001
ORG-[telefon eliminat]+02:00
http://conseildetat.be/?page=e-procedure&lang=fr
Brussels
EUR
Antwerpen / Anvers
Kontich
[telefon eliminat]
CON-0001
2000
Rue de la science 33
a41fc54d-9140-4046-8169-f73c189d7571
no-eu-funds
32014L[telefon eliminat]+01:00
1
BRUXELLES
2661F_1
can-standard
true
2026-11-15+01:00 ••• ••• 07+02:00
ULiège
BE 04 ••• ••• 36
no
[email eliminat]
247000.00
29
BE 09 ••• ••• 66
[email eliminat]
1[telefon eliminat]
TEN-0001
sme
eforms-sdk-1.13
1040
2026-10-08+02:00
RES-0001
LOT-0001
[telefon eliminat]
[email eliminat]
PPP0O5-1439/6706/2661F
TPA-[telefon eliminat]
Boulevard de Colonster 2 - Quartier Village 3 - Bâtiment B9
[telefon eliminat]:00:00+02:00
cost
4000
serv-prov
[email eliminat]
[telefon eliminat]
BE 06 ••• ••• 47
BEL
false
Liège
BE332
BE211
2026-10-14+02:00
[telefon eliminat]
FRA
tenders
Bruker_Belgium_nv
2.3
http://www.uliege.be/
ted-esen
open
Loturi TED
1
2661F_1
Upgrade FTICR 9.4T en solariX 7T 2xR à tête froide
Le présent marché concerne la seconde étape d’un plan de mise à jour de notre instrumentation exceptionnelle, un FT-ICR solariX xR de Bruker (alias détection 1ω) en solariX 2xR (alias détection 2ω), c’est à dire deux cycles de détection par circonvolution des paquets d’ions dans la cellule ICR harmonisée dynamiquement, connue aussi sous le nom de ParaCell. Ce marché inclut l’upgrade de l’électronique pour la détection des ions en mode 2ω, et d’un aimant de seconde main compatible avec la détection 2ω d’au moins 7T et à consommation réduite en hélium liquide. La première étape de l’upgrade de notre FT-ICR comprenait entre autres la mise à jour de l’électronique de détection et de traitement des signaux de l’ICR via l’achat de la console NEO AVANCE. Cette console NEO est compatible avec la détection 2xR via l’ajout d’une carte électronique dédiée, qui fait l’objet de ce marché. Néanmoins la détection 2ω nécessite que les performances de l’aimant supraconducteur, notamment en termes d’homogénéité du champ magnétique, satisfasse les exigences de la détection 2ω. Cela nécessite donc de changer notre aimant supra-conducteur de 9.4T qui équipe actuellement notre solariX. C’est pourquoi un aimant de seconde main, d’au moins 7T, qui répond aux critères de performances imposés par la détection 2ω, fait partie de la demande de ce marché. En outre, et vu le contexte géopolitique actuel qui tend considérablement le marché de l’hélium liquide nécessaire au refroidissement de l’aimant supra-conducteur, l’aimant proposé devra être équipé d’un système dit de « tête froide » ou équivalent qui permet d’espacer annuellement les cycles de remplissage en hélium liquide, au lieu de tous les trimestres, avec l’aimant actuellement disponible au laboratoire de spectrométrie de masse. En plus de favoriser une utilisation de ce spectromètre de masse dans un contexte de développement durable, ce changement d’aimant a aussi pour vocation de pérenniser son fonctionnement via une consommation en hélium liquide nettement réduite car devenu une ressource hautement stratégique (usages militaire, médical, et scientifique) et à la disponibilité fortement limitée.
38433100 — Spectrometre de masa
Rezultate și atribuiri TED
LOT-0001247.000,00 EUR
Câștigător: Bruker Belgium nv · CUI 04 ••• ••• 83
Contract 3991-54857 oct. 20261 oferte primite
Detalii licitație
Descriere
Le présent marché concerne la seconde étape d’un plan de mise à jour de notre instrumentation exceptionnelle, un FT-ICR solariX xR de Bruker (alias détection 1ω) en solariX 2xR (alias détection 2ω), c’est à dire deux cycles de détection par circonvolution des paquets d’ions dans la cellule ICR harmonisée dynamiquement, connue aussi sous le nom de ParaCell. Ce marché inclut l’upgrade de l’électronique pour la détection des ions en mode 2ω, et d’un aimant de seconde main compatible avec la détection 2ω d’au moins 7T et à consommation réduite en hélium liquide. La première étape de l’upgrade de notre FT-ICR comprenait entre autres la mise à jour de l’électronique de détection et de traitement des signaux de l’ICR via l’achat de la console NEO AVANCE. Cette console NEO est compatible avec la détection 2xR via l’ajout d’une carte électronique dédiée, qui fait l’objet de ce marché. Néanmoins la détection 2ω nécessite que les performances de l’aimant supraconducteur, notamment en termes d’homogénéité du champ magnétique, satisfasse les exigences de la détection 2ω. Cela nécessite donc de changer notre aimant supra-conducteur de 9.4T qui équipe actuellement notre solariX. C’est pourquoi un aimant de seconde main, d’au moins 7T, qui répond aux critères de performances imposés par la détection 2ω, fait partie de la demande de ce marché. En outre, et vu le contexte géopolitique actuel qui tend considérablement le marché de l’hélium liquide nécessaire au refroidissement de l’aimant supra-conducteur, l’aimant proposé devra être équipé d’un système dit de « tête froide » ou équivalent qui permet d’espacer annuellement les cycles de remplissage en hélium liquide, au lieu de tous les trimestres, avec l’aimant actuellement disponible au laboratoire de spectrométrie de masse. En plus de favoriser une utilisation de ce spectromètre de masse dans un contexte de développement durable, ce changement d’aimant a aussi pour vocation de pérenniser son fonctionnement via une consommation en hélium liquide nettement réduite car devenu une ressource hautement stratégique (usages militaire, médical, et scientifique) et à la disponibilité fortement limitée.
Căutări relevante pentru 709857-2026
Legături interne utile pentru CPV, autoritate și expresiile principale din denumirea procedurii.