Anunțul 769981-2026 pentru Danemarca – Spectrometre de masă – A Element Analyzer Isotope Ratio Mass Spetrometer,10 kV 253 Plus IRMS architecture este publicat de Københavns Universitet și este încadrat la codul CPV 38433100.
Sinteză HarveyAI
Harvey procesează documentele acestei licitații...
Contactele sunt disponibile utilizatorilor autentificați.Autentifică-te
Textul integral publicat de TEDextinde
Københavns Universitet
A Element Analyzer Isotope Ratio Mass Spetrometer,10 kV 253 Plus IRMS architecture
Klagenævnet for Udbud
Thermo Electron A/S
253 Plus employs a 10 kV acceleration voltage electron-impact ionization source which provides exceptional ion transmission and sensitivity while supporting the stringent linearity required for high-precision isotope ratio measurements. 253 Plus provides optimized sensitivity and linearity operating modes, including: Sensitivity Mode: 600 molecules/ion Linearity Mode: 900 molecules/ion, with linearity of 0.02 ‰/nA This is central to applications requiring the highest level of isotope-ratio performance. The 253 Plus ion-source housing is machined from a single piece of metal not welded components. This minimizes surfaces capable of retaining adsorbed water. Materials that can contribute to memory effects through chemisorption are similarly minimized and replaced by inert materials. This design is particularly important in high-precision IRMS because residual water can contribute to memory and non-linearity. Internal radiant heating and monoblock source architecture provides a highly controlled source environment for demanding stable-isotope measurements. The 253 Plus incorporates VISC, which can be adjusted externally without opening the vacuum system. The 253 Plus ion source is mechanically self-aligning and can only be installed in the correct orientation. The filament is designed as a plug-in module with simplified installation and minimal possibility of incorrect positioning. This reduce maintenance time and minimize the possibility of changes in source alignment following routine maintenance. The 253 Plus platform is differentiated by intellectual property relating to high-performance isotope-ratio detection and dynamic-range enhancement. Transimpedance amplifier technology – Heinz Lerche: UK Pat. GB2526857B USA Pat. US9431976B2 China Pat. CN105305976B Dynamic Range Improvement for Isotope Ratio Mass Spectrometry – Andreas Hilkert, Anne Trinquier, Jens Radke and Johannes Schwieters: USA Pat. US10312071B2 UK Pat. GB2541385B
Mercell Holding ASA
Dele af udstyret er patenteret.
Konkurrence- og Forbrugerstyrelsen
100 %
DNK
01
education
DK050
29979812
Askekroken 11
[email eliminat]
04 ••• ••• 00
none
https://www.kfst.dk
[telefon eliminat]
[telefon eliminat]
supplies
København K
8800
Nørregade 10
Viborg
[telefon eliminat]
CON-0001
1350
quality
0
32014L0024
1
per-exa
2030-12-31Z
can-standard
Allerød
http://www.ku.dk/
2000-01-01Z
https://naevneneshus.dk/start-din-klage/klagenaevnet-for-udbud/
9af55bf7-800d-4b50-9188-b1e36af57cef-01
body-pl
37795526
29
TEN-0001
eforms-sdk-1.13
RES-0001
Nævnenes Hus, Toldboden 2
38433100
Peter Lintrup
[telefon eliminat]
complainants
980921565
[email eliminat]
DAN
Gydevang 33
0277
Carl Jacobsens vej 35
2.3
København k
ted-esen
2026-11-05+01:00 ••• ••• 19
neg-wo-call
selec-w
08:30:08+00:00
DK011
DK013
2500
ORG-0003
ORG-0004
ORG-0005
ORG-0001
a9276fe2-92ee-411a-bb3e-f3b5fb9110fe
ORG-0002
Oslo
-1
DKK
[telefon eliminat]
NO081
3450
no-eu-funds
NOR
698ba6b3-f1c6-4866-9c13-8e69549c8678
215/2026
https://eu.eu-supply.com/ctm/company/companyinformation/index/166597
true
win-ten-val
eSender
no
technical
eo-int
1165
http://mercell.com/
medium
LOT-0000
DK28314388
TPA-0001
[email eliminat]
false
[email eliminat]
08:30:39+00:00 ••• ••• 04+00:00
Valby
100
[telefon eliminat]
tenders
not-val
Øster Voldgade 5-7
Loturi TED
1
0431-0120/26-7000
A Element Analyzer Isotope Ratio Mass Spetrometer,10 kV 253 Plus IRMS architecture
253 Plus employs a 10 kV acceleration voltage electron-impact ionization source which provides exceptional ion transmission and sensitivity while supporting the stringent linearity required for high-precision isotope ratio measurements. 253 Plus provides optimized sensitivity and linearity operating modes, including: Sensitivity Mode: 600 molecules/ion Linearity Mode: 900 molecules/ion, with linearity of 0.02 ‰/nA This is central to applications requiring the highest level of isotope-ratio performance. The 253 Plus ion-source housing is machined from a single piece of metal not welded components. This minimizes surfaces capable of retaining adsorbed water. Materials that can contribute to memory effects through chemisorption are similarly minimized and replaced by inert materials. This design is particularly important in high-precision IRMS because residual water can contribute to memory and non-linearity. Internal radiant heating and monoblock source architecture provides a highly controlled source environment for demanding stable-isotope measurements. The 253 Plus incorporates VISC, which can be adjusted externally without opening the vacuum system. The 253 Plus ion source is mechanically self-aligning and can only be installed in the correct orientation. The filament is designed as a plug-in module with simplified installation and minimal possibility of incorrect positioning. This reduce maintenance time and minimize the possibility of changes in source alignment following routine maintenance. The 253 Plus platform is differentiated by intellectual property relating to high-performance isotope-ratio detection and dynamic-range enhancement. Transimpedance amplifier technology – Heinz Lerche: UK Pat. GB2526857B USA Pat. US9431976B2 China Pat. CN105305976B Dynamic Range Improvement for Isotope Ratio Mass Spectrometry – Andreas Hilkert, Anne Trinquier, Jens Radke and Johannes Schwieters: USA Pat. US10312071B2 UK Pat. GB2541385B
38433100 — Spectrometre de masa
Rezultate și atribuiri TED
LOT-0000
Câștigător: Thermo Electron A/S · CUI DK28314388
Contract 04 ••• ••• 001 oferte primite
Detalii licitație
Descriere
253 Plus employs a 10 kV acceleration voltage electron-impact ionization source which provides exceptional ion transmission and sensitivity while supporting the stringent linearity required for high-precision isotope ratio measurements. 253 Plus provides optimized sensitivity and linearity operating modes, including: Sensitivity Mode: 600 molecules/ion Linearity Mode: 900 molecules/ion, with linearity of 0.02 ‰/nA This is central to applications requiring the highest level of isotope-ratio performance. The 253 Plus ion-source housing is machined from a single piece of metal not welded components. This minimizes surfaces capable of retaining adsorbed water. Materials that can contribute to memory effects through chemisorption are similarly minimized and replaced by inert materials. This design is particularly important in high-precision IRMS because residual water can contribute to memory and non-linearity. Internal radiant heating and monoblock source architecture provides a highly controlled source environment for demanding stable-isotope measurements. The 253 Plus incorporates VISC, which can be adjusted externally without opening the vacuum system. The 253 Plus ion source is mechanically self-aligning and can only be installed in the correct orientation. The filament is designed as a plug-in module with simplified installation and minimal possibility of incorrect positioning. This reduce maintenance time and minimize the possibility of changes in source alignment following routine maintenance. The 253 Plus platform is differentiated by intellectual property relating to high-performance isotope-ratio detection and dynamic-range enhancement. Transimpedance amplifier technology – Heinz Lerche: UK Pat. GB2526857B USA Pat. US9431976B2 China Pat. CN105305976B Dynamic Range Improvement for Isotope Ratio Mass Spectrometry – Andreas Hilkert, Anne Trinquier, Jens Radke and Johannes Schwieters: USA Pat. US10312071B2 UK Pat. GB2541385B
Căutări relevante pentru 769981-2026
Legături interne utile pentru CPV, autoritate și expresiile principale din denumirea procedurii.